Overview
ET100 equips with a pt100 and a transmitter, pt100 is used to sensing the changes of medium temperature, the transmitter will convert the changes to industrial signal and output.
Specifications
Measuring range
-58...392°F / -50…200°C
Accuracy
0.5K + 0.4% of full span
Resolution
< 0.5% of full span
Process pressure
Ø6 probe: 580 psi / 40 bar
Ø8 probe: 1450 psi / 100 bar
Output
4…20mA
Wetted parts material
304 or 316L stainless steel selectable
Wiring protection
Reverse polarity, Over-voltage
Electrical connection
Hirschmann plug
Applications
Hydraulic and lubrication system
Cooling system
Heating system
Water supply system
Benefits
Compact design
Cost efficiency